Calculadora de Aislamiento de Muros — m, R-value, cost
Como usar esta calculadora
Ingrese las dimensiones del muro using one of three methods: single wall (length x height), room perimeter (width x length x height), or direct area in square meters. Choose the unit (m, cm, or mm) from the dropdown. Specify door y ventanas to subtract from gross area. Choose insulation type (batt/roll, blown-in, spray foam, or rigid board), separacion de montantes, and profundidad de cavidad del muro. Los resultados se actualizan al instante.
Costo — ingrese el precio por panel/bolsa/kit/hoja para obtener el costo total. Seleccione su moneda (EUR, PLN, CZK, etc.).
Barrera de vapor — calculo opcional de capa de control de vapor PE basado en el area neta del muro.
Guia de valor U — valores U recomendados por EN ISO 6946 mostrados como referencia.
U = 1/Rtotal (includes surface resistances Rsi=0.13, Rse=0.04 m2K/W per EN ISO 6946)
Country examples: DE: U ≤ 0.24 | FR: U ≤ 0.28 | PL: U ≤ 0.20 | CZ: U ≤ 0.30 | SE: U ≤ 0.18
Calculos guardados
| Hora | Metodo | m2 netos | Tipo | R-value | U-value | Cant. | Ins | VB | Total |
|---|
How to Calculate Wall Insulation (Metric)
Esta calculadora de aislamiento de muros estima la cantidad de insulation necesario para muros residenciales y comerciales cavidades de muro using metric dimensions. Ingrese las dimensiones del muro in meters, centimeters, or millimeters, reste las aberturas de puertas y ventanas, and elija entre four insulation types: mineral wool or fiberglass batts, blown-in cellulose or fiberglass, open-cell or closed-cell spray foam, and rigid foam board (XPS, EPS, Polyiso). La calculadora tiene en cuenta separacion de montantes (400 or 600 mm on center) and profundidad de cavidad del muro (89 mm, 140 mm, or 200 mm).
Thermal Resistance and U-value
R-value (m2K/W) measures thermal resistance per EN ISO 6946. U-value (W/m2K) = 1/Rtotal where Rtotal includes surface resistances (Rsi=0.13 and Rse=0.04 m2K/W). Typical wall R-values: 2.3 m2K/W for 89 mm mineral wool, 3.7 m2K/W for 140 mm, and 5.3 m2K/W for 200 mm. Spray foam provides the highest R-value per thickness: closed-cell at ~0.045 W/mK vs mineral wool at ~0.035 W/mK.
Formulas
Area neta del muro = area bruta del muro - (doors x 1.89 m2) - (windows x avg W x avg H). Insulation packages = ceil(net area x (1 + waste%) / cobertura por package). R-value = thickness / thermal conductivity. U-value = 1 / (Rsi + Rinsulation + Rse).
Preguntas frecuentes
Do I need a vapour barrier? En climas frios, a PE vapour control layer on the warm side of insulation prevents interstitial condensation per EN 13788. Check local building regulations. Puedo combinar tipos de aislamiento? Yes, rigid board (aislamiento continuo) se agrega frecuentemente sobre batt-insulated walls to reduce thermal bridging per EN ISO 10211.