Calculadora de Membrana Impermeabilizante — ft, sq ft, cost

Dimensiones en pies, pulgadas · Membrane quantity in gal, rolls, sheets · Cost estimate
ASTM D6153 / ICC-ES
Cambiar a version metrica →

Como usar esta calculadora

Seleccione el tipo de superficie — muro de cimentacion (perimetro × profundidad), losa/piso, terraza/balcon, o ingrese area personalizada. Elija el tipo de membrana: liquida aplicada, lamina (autoadhesiva), placa de drenaje, o membrana con protuberancias. Los resultados se actualizan con cantidad de membrana, primer opcional, cinta para juntas y costo.

Liquida aplicada — cobertura en ft2/gal a 60 mil de espesor de pelicula seca.
Membrana laminar — rollos autoadhesivos de 36″ de ancho, traslape de 6″.
Placa de drenaje — hojas de 4'x50' (200 ft2).
Membrana con protuberancias — rollos de 4'x50' (200 ft2).

Foundation wall Below-grade slab Deck/balcony 60 mil DFT
Surface Type & Dimensions
Foundation perimeter × wall depth below grade
ft in
ft in
5% simple · 10% typical · 15% complex with penetrations
%
Diagram
Secciones opcionales:
$Membrane Price
$
liquid applied, per gallon
Primer
$
Primer coverage: ~300 ft² per gallon
Cinta para juntas
$
4″ seam tape, 75 ft per roll
Resultados
Membrane
Galones necesarios
gal
Area de la superficie
ft²
Area + Waste
ft²
Cobertura
ft²/gal

Calculos guardados

HoraSurfaceArea ft²TipoCant.Cost
Sin calculos guardados

How to Calculate Waterproofing Membrane

Esta calculadora estima membrane quantity for foundation muros, slabs, decks, and custom areas. Choose from liquid applied (coverage ~25 ft²/gal at 60 mil DFT), peel-and-stick sheet membrane (36″ wide rolls with 6″ overlap), drain board, or dimple mat (4′×50′ sheets).

Formulas

Liquid: gallons = area / cobertura por gallon. Sheet: rolls = area / (roll width × roll length × effective coverage factor). Drain board / dimple mat: sheets = area / 200 ft². Seam tape: linear feet = number of seams × seam length. Primer: gallons = area / 300.

Application Standards

ASTM D6153 for self-adhered sheet membranes. ICC-ES evaluation reports for liquid membranes. Minimo 60 mil DFT (dry film thickness) for below-grade waterproofing. Two coats recommended for liquid applied systems.

Preguntas frecuentes

Do I need primer? Most peel-and-stick and liquid membranes require primer on concrete surfaces. Check manufacturer specs. Drain board vs dimple mat? Both protect the membrane and facilitate drainage. Drain boards add R-value; dimple mats are more economical.

Misha Noyr, M.Eng.

Misha Noyr, M.Eng.

Civil Engineer · 15+ yrs · structural design, geotechnics. Full bio →